Input Voltage Rating |
1Φ200-240Vac |
Wiring |
Hardwired |
Max. Input Current |
48A / 80A @208-240Vac |
Input Protection |
UVP, OVP, SPD, RCD, Ground Fault Protection, |
Max. Output Power |
AC 11.5kW / 19.2 kW |
Voltage Accuracy |
±2% |
Current Accuracy |
±2% |
Output Voltage Range |
208 ±10% or 240 VAC ±10% |
Maximum Output Current |
11.5kW / 19.2 kW |
Output Protection |
UVP, OVP, OCP, OTP, SPD, RCD, Ground Fault Protection, Control Pilot Fault Protection |
Power Factor |
0.99 |
Efficiency |
>96% |
Cooling |
Passive |
Standby Power |
< 5W |
Electrical Isolation |
Input and Output Isolation |
Internal Protection |
OVP, UVP, OCP, RCD, (CCID 20), Ground Fault Protection |
Max. Connectors per Unit |
Dual |
Supported Connector Types |
SAE J1772 Type 1 |
Cable Lengths |
18 ft |
Display |
4.3 Inch LCD Display |
Communication |
Ethernet, Wi-Fi, 4G Cellular |
Back-end Support |
OCPP 1.6 JSON |
User Authentication |
RFID, QR Code |
Remote Load Management |
Via OCPP 1.6 JSON |
Safety |
UL2231, UL2594 |
FCC Compliant |
YES |
Ingress Protection |
Charger: IP65, Cable: IP54, NEMA 3 |
Anti-Vandalism |
IK08,excluding LCD & RFID |
Dedicated Breaker Rating |
60 A / 100 Amp |
Operational Temperature |
-22°F - 122°F |
Storage Temperature |
-40°F - 158°F |
Relative Humidity |
MAX 95% RH, non-condensing |
Altitude |
< 6,561 FT (2000m) |
Dimensions |
13.4 x 4.4 x 18.5 inch |
Weight |
18.1 / 19.8 Lbs |